DC-1 Digital Controller
Installation and
Calibration
Mute Level
Power On Volume
Zone 2 Volume
Selecting LIMITER ADJUST in the Sub Peak Limiter menu invokes a
calibration routine for setting the optimal peak level for your installation.
Pressing SELECT routes low frequency calibration noise to the subwoofer
output of the DC-1. A two-line display indicates the LIMITER LEVEL
setting in dB on the top line with a bar at the bottom to indicate relative noise
level. Press MENU and to adjust the noise level to the highest level that
your equipment can reproduce without overload.
Be sure the limiter is set to ON before exiting. Press DONE to exit and
automatically set the limiter to the level you have selected.
This menu allows you to set the level of attenuation used whenever the
DC-1 MUTE function is engaged. In the Output Levels menu, attenuation
levels of -10dB, -20dB, -30dB, -40dB, and FULL are available.
This control in the Output Levels menu allows you to select the volume at
which the DC-1 will power on. You can choose from a range of -80 to +12dB,
or elect to have the system power on at the last level used (LAST LVL).
This control in the Output Levels menu allows you to select the initial
volume level for Zone 2. You can choose from a range of -80 to +12dB, or
elect to have Zone 2 power on at the last level used (LAST LVL).
Keep in mind that the Sub Peak
Limiter is separate from the
Subwoofer level control in the Effect
Adjust menus one setting does
not affect the other.